Conventional Detectors

 
 
  A comprehensive range of conventional detectors are available to operate with the Cooper conventional panel range.
 

Benefits and Features

  • LPCB 3rd party approved / CPD approved
  • Low profile design
  • 360° viewable LED design
  • Removable detector chamber for cleaning
  • Common mounting base
  • New enhanced detectors feature Dual LEDs,
  • Drift compensation and Chamber monitoring (Optical & Photo-Thermal)
 
  Specification:
 
Model (UNB)

CPD321

CPT341

CFR330

CMT360

CHT390

Description

Optical Sensor

Photo-Themal Sensor

Heat Sensor (Fast)

Heat Sensor (Med)

Heat Sensor (High)

CPD approved product

0832CPD0633

0832CPD0629

0832CPD0233

0832CPD0236

0832CPD0237

Standards

EN54 pt7:2000

EN54 pt7:2000

EN54 pt5:2000 + A1:2002

+ A1:2002

+ A1:2002

   

 

 

EN54 pt5:2000

 

 

 

 

+ A1:2002

 

 

 

Area coverage

100m² (subject to local standard)

50m² (subject to local standard)

System wiring

2 core

Indication

360° visibility light pipe

Mounting

Surface mount CDBB300, FXN520 base

Compatibility

Conventional fire panels

Detetion Mode

Light scatter principle

Light scatter principle

Heat sensitive element

 

 heat sensitive element

 

 

 

Operating voltage

15 to 30V dc

Max stand by current

30μA

Max Start up current

340μA

 

Max alarm current

25mA

Heat class

 

A2S

A2R

BS

CS

Alarm temperature

 

60°C

 

77°C

92°C

Environmental

 

 

 

 

 

Application

Indoor use IP 40

Temperature

-20°C to 60°C

-20°C to 45°C

-20°C to 60°C

-20°C to 60°C

-20°C to 75°C

Humidity

0 to 95% non condensing

EMC

CE marked

Construction

 

 

 

 

 

Material

PC/ABS

Colour

White

Dimensions

 

 

 

 

 

Excluding Base (Dia x H)

 

100mm x 43mm

Including Base (Dia x H)

100mm x 45mm

101mm x 55mm

 

Technical Documents
Detectors Datasheet

 

 

Intelligent Addressable Sensors

   
 
This range of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems.

 

All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors).

 

 

Product Description:    
This range of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems.

 

All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors).

 

The optical sensor (CAP320) is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

 

The photo-thermal sensor (CAPT340) will respond quickly to fast clean burning fires yet maintain the advantage of optical sensors when detecting smouldering fires. The thermal enhancement of this sensor allows a higher alarm threshold which provides a greater rejection of false alarms. The sensor will also raise an alarm at temperatures exceeding 60ºC.

 

The heat sensor (CAH330) can be set to one of 3 modes 77ºC / 92ºC and rate of rise. These sensors are designed to be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions.

 

  Features
  • Soft addressed
  • Integral short circuit isolator
  • Single address
  • Wide range of sensor types
  • 360° visibility LED using lightpipe technology
  • Drift compensation
  • Removable detector chamber
  • Aesthetically pleasing
  •  

    Benefits
  • Quick and simple to install
  • Single "multi-mode" heat sensor
  • Wide viewing angle for increased LED visibility
  • Common mounting base
  • Positive "lock" indication
  • Discreet design for incorporation into any decor
  • Easy to maintain/service
  •  
     
     
      Specification:
     
    Model

    CAP320

    CAPT340

    CAH330

    Standards

    EN54 pt7:2000 + A1:2002

    EN54 pt7:2000 + A1:2002
    EN54 pt5:2000 + A1:2002

    EN54 pt5:2000 + A1:2002

    Area coverage

    100m² (subject to local standard)

    50m² (subject to local standard)

    System wiring

    Min. 1.5mm, 2 core loop or spur

    Indication

    360° visibility light pipe

    Mounting

    Surface mount CAB300 base

    Compatibility

    CF range of analogue panels

    Addressing mode

    Auto address

    Operating voltage

    18 to 30V dc

    Max standby current

    220μA

    Max alarm current

    5mA

    Heat class
    Rate of rise

    NA

    A1S

    A1R

    Fixed 60ºC

    NA

    NA

    BS

    Fixed 90ºC

    NA

    NA

    CS

    Alarm temperature (static)
    AIR

    NA

    60ºC

    60ºC

    BS

    NA

    NA

    77ºC

    CS

    NA

    NA

    90ºC

    Environmental
    Application

    Indoor use IP 40

    Temperature

    -20°C to 60°C

    -20°C to 50°C

    -20°C to 60°C

    Humidity

    0 to 95% non condensing

    Construction
    Material

    PC/ABS

    Colour

    White

    Dimensions
    (excl. Base) (mm)

    101 (Dia) x 33 (H)

    101 (Dia) x 43 (H)

    101 (Dia) x 43 (H)

    (incl. Base) (mm)

    104 (Dia) x 45 (H)

    104 (Dia) x 55 (H)

    104 (Dia) x 55 (H)

    Weight

    76g (without base)

    Technical Documents
    Sensors Datasheet
     

    HOME  |   ABOUT  |     PRODUCTS   |  SOLUTIONS  |  SERVICES  |  SUPPORT  |  CONTACT

    Copyright ©2010-2015 Al-Masder Al-Motataoer Co.  All Rights Reserved  ::  Designed By Al-Masder